VW Golf Mk7 manualsGolf Mk7 / manual

Volkswagen Golf Mk7 Service & Repair Manual: Refrigerant circuit with expansion valve

This table gives the exact pressure (bar) and temperature (°C) at every point in the expansion valve refrigerant circuit design on the Volkswagen Golf Mk7 — low-pressure side (A) and high-pressure side (B).

A- low-pressure side of the refrigerant circuit.
B- high-pressure side of the refrigerant circuit.

Refrigerant circuit with expansion valve
 

     
Component Overall state of the refrigerant Pressure (in bar) Temperature in degrees Celsius
-1- evaporator, from inlet to outlet Vapour approx. 1.2 bar → Remark approx. -7°C → Remark
    (approx. 1.8 bar) → Remark approx. -1°C → Remark
-2- Air conditioning system compressor A-side Gas approx. 1.2 bar → Remark approx. -1°C
    (approx. 1.8 bar) → Remark (approx. +1°C) → Remark
-3- Air conditioning system compressor B-side Gas approx. 14 bar approx. +65°C
-4- Condenser Gas, vapour, liquid approx. 14 bar at outlet approx. + 55°C
-5- Receiver Liquid approx. 14 bar approx. +55°C
-6- Extraction and charging valve, B side Liquid approx. 14 bar approx. +55°C
-7-Expansion valve Liquid, released into vapour approx. 14 bar approx. +55°C, reduced to -7°C
-8- Extraction and charging valve, A side Gas approx. 1.2 bar → Remark approx. -7°C → Remark
    (approx. 1.8 bar) → Remark approx. -1°C → Remark
 
1)  The pressure in refrigerant circuits with regulating air conditioner compressor is held to approx. 2 bar despite changing heat transport and differing engine speeds. This applies however only within the rated range of the air conditioner compressor; if the rated range of the air conditioner compressor is exceeded, the pressure will increase → Chapter.
2)  The temperature in refrigerant circuits with regulating air conditioner compressor is held within the regulation range of the air conditioner compressor despite changing heat transport and differing engine speeds. This applies however only within the rated range of the air conditioner compressor; if the rated range of the air conditioner compressor is exceeded, the temperature will increase. → Chapter
3)  Measured values for air conditioning systems with two evaporators
  Note
Air conditioning system compressors that do not self-regulate their load are switched off by the respective control unit via the air conditioner compressor regulating valve -N280- when an evaporator temperature less than 0°C is sensed.
In vehicles with air conditioner compressor regulating valve -N280-, the pressure on the low-pressure side is varied by activating the valve.
   

    Questions & answers

    Refrigerant circuit with expansion valve — Volkswagen Golf Mk7

    What pressures appear in the Golf Mk7 expansion valve AC circuit?
    Diagram shows high-pressure (hot gas from compressor → condenser → receiver → valve) and low-pressure (evaporator → suction line → compressor).
    Pressures and temperatures in the refrigerant circuit
      WARNING When working on the refrigerant circuit, observe generally applicable safety rules and the Regulations for ...

    Refrigerant circuit with restrictor and reservoir
    Arrows show the direction of refrigerant flow. A- low-pressure side of the refrigerant circuit. B- high-pressure side of the refrigerant circuit.   ...