Volkswagen Golf Mk7 Service & Repair Manual: Before operating the air conditioning system after recharging with refrigerant

After installing a new compressor or fresh refrigerant oil on the Volkswagen Golf Mk7, this page requires turning the compressor pulley 10 revolutions by hand before starting the engine.

After installing a new air conditioner compressor or filling with fresh refrigerant oil (e.g. after blowing out refrigerant circuit), turn compressor pulley 10 revolutions by hand before starting engine. This will prevent damage to the air conditioner compressor.
–  On 5-cyl. or 10-cyl. diesel engine, turn air conditioner compressor at overload protection 10 times by hand. Then install compressor. This will prevent damage to the air conditioner compressor.
–  Start the engine with the air conditioning system switched off (the air conditioning system magnetic clutch -N25- and the air conditioner compressor regulating valve -N280- are not activated).
–  After the engine has stabilised at its idling speed, switch on the air conditioner compressor and allow the engine to idle for at least 10 minutes at maximum cooling power.

    Questions & answers

    Before operating the air conditioning system after recharging with refrigerant — Volkswagen Golf Mk7

    What must I do after recharging the Golf Mk7 AC system?
    After installing a new compressor or fresh oil, turn the compressor pulley 10 times by hand to distribute oil before starting the engine.
    O-ring
    Use only O-rings that are resistant to refrigerant R134a and related refrigerant oils. O-rings are no longer colour-coded. Coloured and black O-rings are used. ...

    General information on refrigerant circuit
    ...