VW Golf Mk7 manualsGolf Mk7 / manual

Volkswagen Golf Mk7 Service & Repair Manual: Restrictor

The restrictor creates a flow limitation that separates the high-pressure and low-pressure sides of the Volkswagen Golf Mk7 refrigerant circuit — one of two alternative metering designs used across variants.

The restrictor creates a restriction. This restriction limits the flow, separating the high-pressure and low-pressure sides in the refrigerant circuit. Upstream of the restrictor, the refrigerant is warm due to the high pressure. Downstream of the restrictor, the refrigerant is cold due to the low pressure. Upstream of the narrow point is a strainer to catch dirt and downstream of the narrow point is a strainer to atomise the refrigerant before it enters the evaporator.
  Note
Arrow -A- on the restrictor points to the evaporator.
Renew it every time the refrigerant circuit is opened.
Observe different versions.
→ Rep. gr.87
→ Parts catalogue
 

Restrictor

    Questions & answers

    Restrictor — Volkswagen Golf Mk7

    What does the restrictor do in the Golf Mk7 AC system?
    Creates a flow restriction that separates the high-pressure and low-pressure sides, causing the refrigerant to drop in pressure and begin evaporating.
    Reservoir
    The reservoir collects the vaporised and gaseous mixture coming from the evaporator to ensure the air conditioner compressor receives only gaseous refrigerant. Gaseou ...

    Receiver
    The receiver collects the liquid droplets and directs them in a continuous stream to the expansion valve. Moisture which has entered the refrigerant circuit during as ...