Caution
| Missing anti-corrosion treatment results in damage
to the onboard supply. |
|
Note
| All threaded connections must be tightened to specified
torque. |
| Always use hose supplied with anticorrosive agent tin.
|
| Use protection wax for cold area. |
| Use cavity sealing agent for warm area. |
| The sealing agent independently reaches the respective
points through capillary action. |
|
|
|
| – |
Hold injector below ring terminal and spray pin all around. |
|
|
|
| – |
Hold injector above ring terminal and spray pin and wiring
eye all around. |
|
|
|
Questions & answers
Anti-corrosion treatment — Volkswagen Golf Mk7
What anti-corrosion treatment applies to Golf Mk7 electrical connections?
Apply VW-approved contact grease to all cleaned terminals and ground points. This prevents galvanic corrosion and ensures reliable contact.
Special tools and workshop equipment
required
VAG 1331
Note
The u ...
Note
Do not repair Lambda probe wires, since this can result in
malfunctions.
If necessary, replace attachment parts, cabl ...